Metal Underground Water Pipes under certain conditions.
#CONCRETE ENCASED ELECTRODE UPDATE#
UPDATE YOUR SUBSCRIPTION PREFERENCES: Subscribe or Unsubscribe from this list.Section 250.52 provides a list of what items can be used as a grounding electrode.

In addition, this correspondence is neither intended, nor should it be relied upon, to provide professional consultation or services. This correspondence is not a formal interpretation of the NEC® and any responses expressed to the questions are opinions and do not necessarily represent the official position of NECA, NFPA, the NEC Correlating Committee any Code-making panel or other electrical technical committee. IMPORTANT NOTICE: Unless the question requests a response based on a specific edition, all answers are based on the latest edition of NFPA 70® National Electrical Code®.
#CONCRETE ENCASED ELECTRODE FULL#
View a full listing of available resources and products » NECA SAFETY PRODUCTS & PUBLICATIONS: NECA produces electrical safety publications and products for the industry including jobsite safety guides, handbooks and resource kits.
#CONCRETE ENCASED ELECTRODE PDF#
NEIS can be purchased in the NECA Store in three formats: a printed or PDF download of a standard or, as an annual subscription service. NECA STANDARDS: NECA publishes the National Electrical Installation Standards™ (NEIS™), a series of ANSI-approved performance and quality standards for electrical construction. NECA continues to maintain this question forum for its many subscribers in memory and recognition of all his significant contributions to making the NEC what it is today. Even though Charlie passed away in October of 2015, his work continues in spirit. In 2006 Charlie was awarded the prestigious Coggeshall Award for outstanding contributions to the electrical contracting industry, codes and standards development, and technical training. He served on several NEC® technical committees and is past chairman of CMP-12. Trout, better known as Charlie, was a nationally known NEC® expert and author. SUBMIT YOUR CODE QUESTION: Click here to submit a question to for inclusion in an upcoming edition of the Code Question of the Day, or email TROUT: Charles M. The daily distribution of Q&A generates a lively dialogue and shares relative Code-based practical responses.
#CONCRETE ENCASED ELECTRODE INSTALL#
It is not necessary to install any “made” electrodes such as a “ground ring”, “plate electrode” or “rod or pipe electrodes” where you have a metal underground water pipe and a concrete-encased electrode which will satisfy the supplemental electrode requirements of 250.53(D)(2).ĪBOUT CQD: The Code Question of the Day (CQD) is NECA and ELECTRICAL CONTRACTOR Magazine’s flagship National Electrical Code (NEC®) public forum for the industry, sponsored by EATON. So yes, if you have a metal underground water system and a foundation or footing “present” at the building or structure, the metal underground water piping system and a concrete-encased electrode using either the rebars or 20 ft of bare copper conductor as shown in 250.52(A)(3) must be bonded together and used as the grounding electrode system. The wording “if present” is new in the 2005 NEC and replaces the wording “if available” in the 2002 NEC. NEC 250.50 requires that the grounding electrode described in 250.52(A)(3), a concrete-encased electrode, if present, must be bonded to the grounding electrode system. NEC 250.52(A)(3) describes a concrete-encased electrode. This supplemental electrode must be of a type specified in 250.52(A)(2) through (A)(7). NEC 250.53(D)(2) requires a supplemental electrode where a metal underground water pipe is used as a grounding electrode. Hey Joe, I believe you have it essentially correct.